TCFM-200 of Pressure Tester for Plumbing Valve

The equipment can perform pressure tests on various medium and low pressure gate valves, globe valves, check valves, ball valves, butterfly valves, and diaphragm valves. It can also be used for pipeline connection and radiator pressure test.

Key words:

Product Details

1. uses
The equipment can perform pressure tests on various medium and low pressure gate valves, globe valves, check valves, ball valves, butterfly valves, and diaphragm valves. It can also be used for pipeline connection and radiator pressure test.
2. execution standard
GB/T13927 "industrial valve pressure test"
GB/T3287 "malleable cast iron pipe connection"
JG/T1 "steel column radiator"
JG/T2 "steel plate radiator"
JG3 "heater radiator gray cast iron column radiator"
JG4 "heater radiator gray cast iron wing radiator"
JG/T5 "gray cast iron round wing radiator"
3. main technical indicators:
1. Check the diameter of the valve: DN15-DN200;(other sizes are optional)
2. Maximum test pressure: 6.3MPa;
3. Power: 1KW;
4. Voltage: 380V;
5. Overall dimensions: length 1200 × width 560 × height 1720(mm);
6. Weight: 230KG.
4. product structure principle:
The equipment is composed of the following parts: valve test bench, pipeline pressure system, sample fixture and water tank.
The fixture of this machine adopts flange type and thread type to connect the test pieces, pressurize with electric pressure test pump, and adjust the pressure with pressure regulating valve. The value is displayed by pressure gauge. At the same time, it is equipped with liquid level gauge, which can detect the leakage of the valve through the change of water level of the liquid level gauge.
5. product features:
1, the use of high-pressure plunger pump for water supply pressure, precision pressure regulating valve pressure, accumulator pressure, can be accurately and smoothly adjusted out of the test pressure.
2. Using precision pressure gauge, accurate reading.
3. The glass tube level gauge measures the leakage, which is intuitive and convenient.
4. Different clamping methods are adopted for different samples, and flange-type and threaded valves and radiators are widely used.
6. product configuration:

Serial Number

Configuration Name

Specifications and models

Quantity

Brand or place of origin

1

Host

TCFM-200

1

Jinan Tianchen

2

plunger pump

BM3L

1

Hubei

3

Accumulator

NXQA-0.63

1 Piece

Ningbo

4

Precision pressure gauge

0-16MPa

1 Piece

Shanghai

5

Flange type clamp

DN15-DN200

1 set

Jinan Tianchen

6

Thread type clamp

G3/4、G1、G1.5

1 set

Jinan Tianchen

7

Measuring cylinder

5ml

1 Piece

Jinan

8

Digital electronic timer

Timing range 9 9 minutes 59 seconds

1 Piece

NSH

Product inquiry

We use optional cookies to improve your experience on our website, including through social media connections and to serve personalized advertising based on your online activity. If you reject optional cookies, we will only use cookies that are necessary to provide you with the service.